747-20 Specifications |
|
|
P out continuous |
1200 VA continuous |
|
V line 120 vac 60hz models |
90-135 vac 60hz |
|
V line 230 vac 50hz models |
172-257 vac 50hz |
|
V line 230 vac 60hz models |
172-257 vac 60hz |
|
V out @ 1/3 rated load, 60 vac models |
60 vac |
|
V out @ 1/3 rated load, 90 vac models |
90 vac |
|
I out 60 vac models |
0-20 amps |
|
I out 90 vac models |
0-13 amps |
|
Frequency stability in standby |
+/- 1% |
|
Operating temperature range |
-40 degrees C to +50 degrees C |
|
Regulation - no load to full load |
+/- 2% |
|
Output change @ +/-15% input variation |
+/-1% |
|
V out maximum 60 vac models |
73.2 vac |
|
V out maximum 90 vac models |
108.4 vac |
|
I short circuit @ 117/234 vac input - 60 vac out |
>22 amps |
|
I short circuit @ 117/234 vac input - 90 vac out |
>15 amps |
|
Transfer time - line to standby |
8ms minimum - 16ms maximum |
|
Transfer time - standby to line |
3ms after 15ms fixed delay |
|
V transfer - low voltage - 120 vac models |
95 vac input |
|
V transfer - low voltage - 230 vac models |
190 vac input |
|
V shutdown - 3-battery models |
32.4 vdc |
|
V shutdown - 4-battery models |
43.2 vdc |
|
V charge - set to battery specification |
battery preset |
|
V charge - maximum boost 3-battery |
42.0 vdc |
|
V charge - maximum boost 4-battery |
57.8 vdc |
|
I charge - 3-battery/4-battery - adjustable limit |
5 - 9 amp adjustable limit |